Materiales eléctricos · Piura, PerúAtención a empresas y profesionales
Mi lista 0
SIEMENS Seccionador Portafusible 3NP1, 3 Polos, NH00, 160 A 3NP1133-1CA20 - Siemens 3NP1133-1CA20
SIEMENS

Seccionador Portafusible 3NP1, 3 Polos, NH00, 160 A 3NP1133-1CA20 - Siemens

SKU 3NP1133-1CA20 · Unidad base: unit

Producto Siemens. Referencia del fabricante: 3NP1133-1CA20. SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH00, 160 A, for assembly and installation on mounting plate, Box terminal, Cover level 45 mm Características técnicas: product designation: Fuse switch disconnector; design of the safety monitoring: Without; design of the load switch strip form: No; type of the driving mechanism motor drive: No; number of poles: 3; type of device: For assembly and installation on mounting plate; size of disconnecting link: 00 and 000; size of fuse link: NH000, NH00; let-through current with closed switch maximum: 23 kA; mechanical service life (operating cycles) typical: 2 000; I2t value with closed switch maximum: 223 kA²·s; ● at AC-22 B: 0.65.

Consulta existencias con tu cuenta.

Ingresa o regístrate para consultar el stock registrado.

Ingresar ↗

La solicitud no reserva mercadería ni confirma un pedido.

Consultar ficha técnica ↗

Características del producto

product designation
Fuse switch disconnector
design of the safety monitoring
Without
design of the load switch strip form
No
type of the driving mechanism motor drive
No
number of poles
3
type of device
For assembly and installation on mounting plate
size of disconnecting link
00 and 000
size of fuse link
NH000, NH00
let-through current with closed switch maximum
23 kA
mechanical service life (operating cycles) typical
2 000
I2t value with closed switch maximum
223 kA²·s
● at AC-22 B
0.65
● at AC-23 B
0.45
● with capacitive load
-0.25
fuse system
LV HRC fuse
degree of pollution
3
● rated value
690 V
● with degree of pollution 3 at AC rated value
690 V
● with degree of pollution 2 at AC rated value
1 000 V
power factor at AC-21 B
0.95
surge voltage resistance rated value
8 kV
— at 35 °C rated value
160 A
— at 40 °C rated value
155 A
— at 45 °C rated value
145 A
— at 50 °C rated value
140 A
— at 55 °C rated value
133 A
— at AC-21 B at 240 V rated value
160 A
— at AC-21 B at 400 V rated value
160 A
— at AC-21 B at 500 V rated value
160 A
— at AC-21 B at 690 V rated value
160 A
— at AC-22 B at 240 V rated value
160 A
— at AC-22 B at 400 V rated value
160 A
— at AC-22 B at 500 V rated value
160 A
— at AC-22 B at 690 V rated value
125 A
— at AC-23 B at 690 V rated value
35 A
— at AC-23 B at 500 V rated value
63 A
— at AC-23 B at 400 V rated value
160 A
— at AC-23 B at 240 V rated value
160 A
— at DC-21 B at 120 V rated value
160 A
— at DC-21 B at 240 V rated value
160 A
— at DC-21 B at 440 V rated value
160 A
— at DC-22 B at 120 V rated value
160 A
— at DC-22 B at 240 V rated value
160 A
— at DC-22 B at 440 V rated value
125 A
— at DC-23 B at 120 V rated value
100 A
— at DC-23 B at 240 V rated value
100 A
— at DC-23 B at 440 V rated value
63 A
let-through current with high-speed activation maximum
15 kA
● at AC rated value maximum
690 V
● at DC rated value
440 V
● at DC rated value maximum
440 V
● with closed switch with cover or cable lug cover
IP40
● with closed switch without cover or cable lug cover
IP30
● open
IP20
● with conventional rated thermal current without fuse per pole
5 W
● with conventional rated thermal current without fuse per device
15 W
● for rated value of the current at AC in hot operating state per pole
5.7 W
● of the fuse per fuse maximum
12 W
● with capacitive load at 400 V rated value
72 A
● with capacitive load at 500 V rated value
55 A
WhatsApp