Producto Siemens. Referencia del fabricante: 3NP1143-1DA20. SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH1, 250 A, for assembly and installation on mounting plate, Box terminal, Cover level 70 mm Características técnicas: product designation: Fuse switch disconnector; design of the safety monitoring: Without; design of the load switch strip form: No; type of the driving mechanism motor drive: No; number of poles: 3; type of device: For assembly and installation on mounting plate; size of disconnecting link: 1 and 0; size of fuse link: NH0, NH1; let-through current with closed switch maximum: 32 kA; mechanical service life (operating cycles) typical: 1 600; I2t value with closed switch maximum: 780 kA²·s; ● at AC-22 B: 0.65.

Consulta existencias con tu cuenta.

Ingresa o regístrate para consultar el stock registrado.

Ingresar ↗

La solicitud no reserva mercadería ni confirma un pedido.

Consultar ficha técnica ↗

Características del producto

product designation
Fuse switch disconnector
design of the safety monitoring
Without
design of the load switch strip form
No
type of the driving mechanism motor drive
No
number of poles
3
type of device
For assembly and installation on mounting plate
size of disconnecting link
1 and 0
size of fuse link
NH0, NH1
let-through current with closed switch maximum
32 kA
mechanical service life (operating cycles) typical
1 600
I2t value with closed switch maximum
780 kA²·s
● at AC-22 B
0.65
● at AC-23 B
0.45
● with capacitive load
-0.25
fuse system
LV HRC fuse
degree of pollution
3
● rated value
690 V
● with degree of pollution 3 at AC rated value
690 V
● with degree of pollution 2 at AC rated value
1 000 V
power factor at AC-21 B
0.95
surge voltage resistance rated value
8 kV
— at 35 °C rated value
250 A
— at 40 °C rated value
245 A
— at 45 °C rated value
240 A
— at 50 °C rated value
233 A
— at 55 °C rated value
233 A
— at AC-21 B at 240 V rated value
250 A
— at AC-21 B at 400 V rated value
250 A
— at AC-21 B at 500 V rated value
250 A
— at AC-21 B at 690 V rated value
250 A
— at AC-22 B at 240 V rated value
250 A
— at AC-22 B at 400 V rated value
250 A
— at AC-22 B at 500 V rated value
250 A
— at AC-22 B at 690 V rated value
250 A
— at AC-23 B at 690 V rated value
100 A
— at AC-23 B at 500 V rated value
200 A
— at AC-23 B at 400 V rated value
250 A
— at AC-23 B at 240 V rated value
250 A
— at DC-21 B at 120 V rated value
250 A
— at DC-21 B at 240 V rated value
250 A
— at DC-21 B at 440 V rated value
250 A
— at DC-22 B at 120 V rated value
250 A
— at DC-22 B at 240 V rated value
250 A
— at DC-22 B at 440 V rated value
200 A
— at DC-23 B at 120 V rated value
200 A
— at DC-23 B at 240 V rated value
200 A
— at DC-23 B at 440 V rated value
100 A
let-through current with high-speed activation maximum
25 kA
● at AC rated value maximum
690 V
● at DC rated value
440 V
● at DC rated value maximum
440 V
● with closed switch with cover or cable lug cover
IP40
● with closed switch without cover or cable lug cover
IP30
● open
IP20
● with conventional rated thermal current without fuse per pole
8 W
● with conventional rated thermal current without fuse per device
24 W
● for rated value of the current at AC in hot operating state per pole
9.6 W
● of the fuse per fuse maximum
23 W
● with capacitive load at 400 V rated value
72 A
● with capacitive load at 500 V rated value
55 A