Relé Térmico Electrónico 32 - 115 A Tamaño S3 3RB3046-1XB0 - Siemens
SKU 3RB3046-1XB0 · Unidad base: unit
Producto Siemens. Referencia del fabricante: 3RB3046-1XB0. Overload relay 32...115 A Electronic For motor protection Size S3, Class 10E Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset Características técnicas: product designation: solid-state overload relay; product type designation: 3RB3; size of overload relay: S3; size of contactor can be combined company-specific: S3; power loss [W] for rated value of the current at AC in hot operating state: 4.6 W; ● per pole: 1.53 W; type of calculation of power loss current-dependent: quadratic; insulation voltage with degree of pollution 3 at AC rated value: 1 000 V; surge voltage resistance rated value: 8 kV; ● in networks with ungrounded star point between auxiliary and auxiliary circuit: 300 V; ● in networks with grounded star point between auxiliary and auxiliary circuit: 300 V; ● in networks with ungrounded star point between main and auxiliary circuit: 600 V.
Ingresa o regístrate para consultar el stock registrado.
Ingresar ↗La solicitud no reserva mercadería ni confirma un pedido.
Consultar ficha técnica ↗Características del producto
- product designation
- solid-state overload relay
- product type designation
- 3RB3
- size of overload relay
- S3
- size of contactor can be combined company-specific
- S3
- power loss [W] for rated value of the current at AC in hot operating state
- 4.6 W
- ● per pole
- 1.53 W
- type of calculation of power loss current-dependent
- quadratic
- insulation voltage with degree of pollution 3 at AC rated value
- 1 000 V
- surge voltage resistance rated value
- 8 kV
- ● in networks with ungrounded star point between auxiliary and auxiliary circuit
- 300 V
- ● in networks with grounded star point between auxiliary and auxiliary circuit
- 300 V
- ● in networks with ungrounded star point between main and auxiliary circuit
- 600 V
- ● in networks with grounded star point between main and auxiliary circuit
- 690 V
- shock resistance
- 8 g / 11 ms
- ● according to IEC 60068-2-27
- 15 g / 11 ms; Signaling contact 97 / 98 in position "Tripped": 8g / 11 ms
- vibration resistance
- 1 … 6 Hz, 15 mm; 6 … 500 Hz, 20 m/s²; 10 cycles
- thermal current
- 115 A
- ● with automatic reset typical
- 3 min
- ● with remote-reset
- 0 min
- ● with manual reset
- 0 min
- reference code according to IEC 81346-2
- F
- Substance Prohibitance (day/month/year)
- 03/01/2017
- SVHC substance name
- Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1
- Net Weight
- 0.528 kg
- installation altitude at height above sea level maximum
- 2 000 m
- ● during operation
- -25 ... +60 °C
- ● during storage
- -40 ... +80 °C
- ● during transport
- -40 ... +80 °C
- temperature compensation
- -25 ... +60 °C
- relative humidity during operation
- 10 ... 95 %
- number of poles for main current circuit
- 3
- adjustable current response value current of the current-dependent overload release
- 32 ... 115 A
- ● rated value
- 1 000 V
- ● at AC-3e rated value maximum
- 1 000 V
- operating frequency rated value
- 50 ... 60 Hz
- operational current rated value
- 115 A
- operational current at AC-3e at 400 V rated value
- 115 A
- ● for 3-phase motors at 400 V at 50 Hz
- 18.5 ... 55 kW
- ● for AC motors at 500 V at 50 Hz
- 22 ... 75 kW
- ● for AC motors at 690 V at 50 Hz
- 30 ... 90 kW
- design of the auxiliary switch
- integrated
- number of NC contacts for auxiliary contacts
- 1
- ● note
- for contactor disconnection
- number of NO contacts for auxiliary contacts
- 1
- number of CO contacts for auxiliary contacts
- 0
- ● at 24 V
- 4 A
- ● at 110 V
- 4 A
- ● at 120 V
- 4 A
- ● at 125 V
- 4 A
- ● at 230 V
- 3 A
- ● at 60 V
- 0.55 A
- ● at 220 V
- 0.11 A
- trip class
- CLASS 10E
- design of the overload release
- electronic
- ● at 480 V rated value
- 115 A
- ● at 600 V rated value
- 115 A
- contact rating of auxiliary contacts according to UL
- B600 / R300
- — with type of coordination 1 required
- gG: 315 A
- — with type of coordination 2 required
- gG: 315 A
- ● for short-circuit protection of the auxiliary switch required
- fuse gG: 6 A