SKU 3RH2911-1HA10 · Unidad base: unit

Producto Siemens. Referencia del fabricante: 3RH2911-1HA10. auxiliary switch, on the front, 1 NO, .3/.4, --/--, --/--, --/--, current path: 1 NO, --, --, --, screw terminal, for contactors 3RT2 and contactor relays 3RH2 Características técnicas: product category: Auxiliary switch; product designation: auxiliary switch; design of the product: for snapping onto the front; product type designation: 3RH29; suitability for use: for 3RT2.1, 3RT2.2, 3RT2.3, 3RT2.4, 3RH2; insulation voltage with degree of pollution 3 at AC rated value: 690 V; surge voltage resistance rated value: 6 kV; protection class IP on the front: IP20; mechanical service life (operating cycles) typical: 10 000 000; electrical endurance (operating cycles) at AC-15 at 230 V typical: 200 000; Substance Prohibitance (day/month/year): 10/01/2009; Net Weight: 0.04 g.

Consulta existencias con tu cuenta.

Ingresa o regístrate para consultar el stock registrado.

Ingresar ↗

La solicitud no reserva mercadería ni confirma un pedido.

Consultar ficha técnica ↗

Características del producto

product category
Auxiliary switch
product designation
auxiliary switch
design of the product
for snapping onto the front
product type designation
3RH29
suitability for use
for 3RT2.1, 3RT2.2, 3RT2.3, 3RT2.4, 3RH2
insulation voltage with degree of pollution 3 at AC rated value
690 V
surge voltage resistance rated value
6 kV
protection class IP on the front
IP20
mechanical service life (operating cycles) typical
10 000 000
electrical endurance (operating cycles) at AC-15 at 230 V typical
200 000
Substance Prohibitance (day/month/year)
10/01/2009
Net Weight
0.04 g
● instantaneous contact
0
● lagging switching
0
● leading contact
0
number of CO contacts of auxiliary contacts instantaneous contact
0
operational current at AC-15 at 690 V rated value
1 A
● at 24 V
10 A
● at 230 V
10 A
● at 125 V
6 A
● at 250 V
6 A
operational current of auxiliary contacts at AC-12 maximum
10 A
● at 400 V
3 A
● at 110 V
3 A
● at 220 V
1 A
● at 24 V rated value
10 A
● at 60 V rated value
10 A
● at 110 V rated value
4 A
● at 220 V rated value
2 A
● at 440 V rated value
1.3 A
● at 600 V rated value
0.65 A
● at 48 V
2 A
● at 60 V
2 A
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V
C characteristic: 10 A; 0.4 kA
contact reliability of auxiliary contacts
1 faulty switching per 100 million (17 V, 1 mA)
● during operation
-25 ... +60 °C
● during storage
-55 ... +80 °C
● mirror contact according to IEC 60947-4-1
Yes; with 3RT2
● positively driven operation according to IEC 60947-5-1
Yes
design of the fuse link for short-circuit protection of the auxiliary switch required
gG: 10 A (690 V, 1 kA)
fastening method
snap-on mounting
height
37.5 mm
width
36 mm
depth
43.7 mm
type of electrical connection for auxiliary and control circuit
screw-type terminals
● solid or stranded
0.5 ... 2.5 mm²
● finely stranded with core end processing
0.5 ... 2.5 mm²
— solid or stranded
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
— finely stranded with core end processing
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● for AWG cables for auxiliary contacts
2x (20 ... 16), 2x (18 ... 14)
AWG number as coded connectable conductor cross section for auxiliary contacts
20 ... 14
● global warming potential [CO2 eq] / during manufacturing
0.34 kg
● global warming potential [CO2 eq] / during operation
0.562 kg
● global warming potential [CO2 eq] / after end of life
0.0172 kg
● global warming potential [CO2 eq] / total
0.92 kg
Environmental Confirmations
Yes
EPD Typ II/III (with life cylce assessment)
Yes
CCC
Yes
cULus
Yes
KC
Yes