SIEMENS Contactor Trifásico 9 A Bobina 110 Vac, 1NA, S00 3RT2016-1AF01 - Siemens 3RT2016-1AF01
SIEMENS

Contactor Trifásico 9 A Bobina 110 Vac, 1NA, S00 3RT2016-1AF01 - Siemens

SKU 3RT2016-1AF01 · Unidad base: unit

Producto Siemens. Referencia del fabricante: 3RT2016-1AF01. power contactor, AC-3e/AC-3, 9 A, 4 kW / 400 V, 3-pole, 110 V AC, 50/60 Hz, auxiliary contacts: 1 NO, screw terminal, size: S00 Características técnicas: product designation: Power contactor; product type designation: 3RT2; size of contactor: S00; ● function module for communication: No; ● auxiliary switch: Yes; ● at AC in hot operating state: 0.9 W; ● at AC in hot operating state per pole: 0.3 W; ● without load current share typical: 1.1 W; type of calculation of power loss current-dependent: quadratic; ● of main circuit with degree of pollution 3 rated value: 690 V; ● of auxiliary circuit with degree of pollution 3 rated value: 690 V; ● of main circuit rated value: 6 kV.

Consulta existencias con tu cuenta.

Ingresa o regístrate para consultar el stock registrado.

Ingresar ↗

La solicitud no reserva mercadería ni confirma un pedido.

Consultar ficha técnica ↗

Características del producto

product designation
Power contactor
product type designation
3RT2
size of contactor
S00
● function module for communication
No
● auxiliary switch
Yes
● at AC in hot operating state
0.9 W
● at AC in hot operating state per pole
0.3 W
● without load current share typical
1.1 W
type of calculation of power loss current-dependent
quadratic
● of main circuit with degree of pollution 3 rated value
690 V
● of auxiliary circuit with degree of pollution 3 rated value
690 V
● of main circuit rated value
6 kV
● of auxiliary circuit rated value
6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1
400 V
● at AC
6,7 g / 5 ms, 4,2 g / 10 ms
● of contactor typical
30 000 000
● of the contactor with added electronically optimized auxiliary switch block typical
5 000 000
● of the contactor with added auxiliary switch block typical
10 000 000
reference code according to IEC 81346-2
Q
Substance Prohibitance (day/month/year)
10/01/2009
Net Weight
217.8 g
installation altitude at height above sea level maximum
2 000 m
● during operation
-25 ... +60 °C
● during storage
-55 ... +80 °C
relative humidity minimum
10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum
95 %
number of poles for main current circuit
3
number of NO contacts for main contacts
3
number of NC contacts for main contacts
0
● at AC-3 rated value maximum
690 V
● at AC-3e rated value maximum
690 V
● at AC-1 at 400 V at ambient temperature 40 °C rated value
22 A
— up to 690 V at ambient temperature 40 °C rated value
22 A
— up to 690 V at ambient temperature 60 °C rated value
20 A
— at 400 V rated value
9 A
— at 500 V rated value
7.7 A
— at 690 V rated value
6.7 A
● at AC-4 at 400 V rated value
8.5 A
● at AC-5a up to 690 V rated value
19.4 A
● at AC-5b up to 400 V rated value
7.4 A
— up to 230 V for current peak value n=20 rated value
5.3 A
— up to 400 V for current peak value n=20 rated value
5.3 A
— up to 500 V for current peak value n=20 rated value
5.3 A
— up to 690 V for current peak value n=20 rated value
5 A
— up to 230 V for current peak value n=30 rated value
3.5 A
— up to 400 V for current peak value n=30 rated value
3.5 A
— up to 500 V for current peak value n=30 rated value
3.6 A
— up to 690 V for current peak value n=30 rated value
3.3 A
minimum cross-section in main circuit at maximum AC-1 rated value
4 mm²
● at 400 V rated value
4.1 A
● at 690 V rated value
3.3 A
— at 24 V rated value
20 A
— at 60 V rated value
20 A
— at 110 V rated value
2.1 A
— at 220 V rated value
0.8 A
— at 440 V rated value
0.6 A
— at 600 V rated value
0.6 A
— at 230 V rated value
2.2 kW
● up to 230 V for current peak value n=20 rated value
2 kVA
● up to 400 V for current peak value n=20 rated value
3.6 kVA