Contactor Trifásico 50 A Bobina 220 VAC,1NA+1NC, S2 3RT2036-1AN20 - Siemens
SKU 3RT2036-1AN20 · Unidad base: unit
Producto Siemens. Referencia del fabricante: 3RT2036-1AN20. power contactor, AC-3e/AC-3, 51 A, 22 kW / 400 V, 3-pole, 220 V AC, 50/60 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S2 Características técnicas: product designation: Power contactor; product type designation: 3RT2; size of contactor: S2; ● function module for communication: No; ● auxiliary switch: Yes; ● at AC in hot operating state: 12 W; ● at AC in hot operating state per pole: 4 W; ● without load current share typical: 6.5 W; type of calculation of power loss current-dependent: quadratic; ● of main circuit with degree of pollution 3 rated value: 690 V; ● of auxiliary circuit with degree of pollution 3 rated value: 690 V; ● of main circuit rated value: 6 kV.
Ingresa o regístrate para consultar el stock registrado.
Ingresar ↗La solicitud no reserva mercadería ni confirma un pedido.
Consultar ficha técnica ↗Características del producto
- product designation
- Power contactor
- product type designation
- 3RT2
- size of contactor
- S2
- ● function module for communication
- No
- ● auxiliary switch
- Yes
- ● at AC in hot operating state
- 12 W
- ● at AC in hot operating state per pole
- 4 W
- ● without load current share typical
- 6.5 W
- type of calculation of power loss current-dependent
- quadratic
- ● of main circuit with degree of pollution 3 rated value
- 690 V
- ● of auxiliary circuit with degree of pollution 3 rated value
- 690 V
- ● of main circuit rated value
- 6 kV
- ● of auxiliary circuit rated value
- 6 kV
- maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1
- 400 V
- ● at AC
- 11.8 g / 5 ms, 7.4 g / 10 ms
- ● of contactor typical
- 10 000 000
- ● of the contactor with added electronically optimized auxiliary switch block typical
- 5 000 000
- ● of the contactor with added auxiliary switch block typical
- 10 000 000
- reference code according to IEC 81346-2
- Q
- Substance Prohibitance (day/month/year)
- 10/01/2014
- Net Weight
- 950.8 g
- installation altitude at height above sea level maximum
- 2 000 m
- ● during operation
- -25 ... +60 °C
- ● during storage
- -55 ... +80 °C
- relative humidity minimum
- 10 %
- relative humidity at 55 °C according to IEC 60068-2-30 maximum
- 95 %
- number of poles for main current circuit
- 3
- number of NO contacts for main contacts
- 3
- number of NC contacts for main contacts
- 0
- ● at AC-3 rated value maximum
- 690 V
- ● at AC-3e rated value maximum
- 690 V
- ● at AC-1 at 400 V at ambient temperature 40 °C rated value
- 70 A
- — up to 690 V at ambient temperature 40 °C rated value
- 70 A
- — up to 690 V at ambient temperature 60 °C rated value
- 60 A
- — at 400 V rated value
- 51 A
- — at 500 V rated value
- 51 A
- — at 690 V rated value
- 24 A
- ● at AC-4 at 400 V rated value
- 41 A
- ● at AC-5a up to 690 V rated value
- 61.6 A
- ● at AC-5b up to 400 V rated value
- 41.5 A
- — up to 230 V for current peak value n=20 rated value
- 43.2 A
- — up to 400 V for current peak value n=20 rated value
- 43.2 A
- — up to 500 V for current peak value n=20 rated value
- 43.2 A
- — up to 690 V for current peak value n=20 rated value
- 24 A
- — up to 230 V for current peak value n=30 rated value
- 28.8 A
- — up to 400 V for current peak value n=30 rated value
- 28.8 A
- — up to 500 V for current peak value n=30 rated value
- 28.8 A
- — up to 690 V for current peak value n=30 rated value
- 24 A
- minimum cross-section in main circuit at maximum AC-1 rated value
- 25 mm²
- ● at 400 V rated value
- 24 A
- ● at 690 V rated value
- 20 A
- — at 24 V rated value
- 55 A
- — at 60 V rated value
- 23 A
- — at 110 V rated value
- 4.5 A
- — at 220 V rated value
- 1 A
- — at 440 V rated value
- 0.4 A
- — at 600 V rated value
- 0.25 A
- ● at AC-2 at 400 V rated value
- 22 kW
- — at 230 V rated value
- 15 kW
- ● up to 230 V for current peak value n=20 rated value
- 17.2 kVA