Materiales eléctricos · Piura, PerúAtención a empresas y profesionales
Mi lista 0
SIEMENS Relé Térmico 70-90A S3 - 3RU2146-4LB0 - Siemens 3RU2146-4LB0
SIEMENS

Relé Térmico 70-90A S3 - 3RU2146-4LB0 - Siemens

SKU 3RU2146-4LB0 · Unidad base: unit

Producto Siemens. Referencia del fabricante: 3RU2146-4LB0. Overload relay 70...90 A Thermal For motor protection Size S3, Class 10 Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset Características técnicas: product designation: thermal overload relay; product type designation: 3RU2; size of overload relay: S3; size of contactor can be combined company-specific: S3; power loss [W] for rated value of the current at AC in hot operating state: 21 W; ● per pole: 7 W; type of calculation of power loss current-dependent: quadratic; insulation voltage with degree of pollution 3 at AC rated value: 1 000 V; surge voltage resistance rated value: 8 kV; ● in networks with ungrounded star point between auxiliary and auxiliary circuit: 440 V; ● in networks with grounded star point between auxiliary and auxiliary circuit: 440 V; ● in networks with ungrounded star point between main and auxiliary circuit: 440 V.

Consulta existencias con tu cuenta.

Ingresa o regístrate para consultar el stock registrado.

Ingresar ↗

La solicitud no reserva mercadería ni confirma un pedido.

Consultar ficha técnica ↗

Características del producto

product designation
thermal overload relay
product type designation
3RU2
size of overload relay
S3
size of contactor can be combined company-specific
S3
power loss [W] for rated value of the current at AC in hot operating state
21 W
● per pole
7 W
type of calculation of power loss current-dependent
quadratic
insulation voltage with degree of pollution 3 at AC rated value
1 000 V
surge voltage resistance rated value
8 kV
● in networks with ungrounded star point between auxiliary and auxiliary circuit
440 V
● in networks with grounded star point between auxiliary and auxiliary circuit
440 V
● in networks with ungrounded star point between main and auxiliary circuit
440 V
● in networks with grounded star point between main and auxiliary circuit
440 V
shock resistance according to IEC 60068-2-27
8g / 11 ms
● with automatic reset typical
10 min
● with remote-reset
10 min
● with manual reset
10 min
reference code according to IEC 81346-2
F
Substance Prohibitance (day/month/year)
03/01/2017
Net Weight
0.554 kg
installation altitude at height above sea level maximum
2 000 m
● during operation
-40 ... +70 °C
● during storage
-55 ... +80 °C
● during transport
-55 ... +80 °C
temperature compensation
-40 ... +60 °C
relative humidity during operation
10 ... 95 %
number of poles for main current circuit
3
adjustable current response value current of the current-dependent overload release
70 ... 90 A
● rated value
1 000 V
● at AC-3e rated value maximum
1 000 V
operating frequency rated value
50 ... 60 Hz
operational current rated value
90 A
operational current at AC-3e at 400 V rated value
90 A
— at 400 V rated value
45 kW
— at 500 V rated value
55 kW
— at 690 V rated value
75 kW
design of the auxiliary switch
integrated
number of NC contacts for auxiliary contacts
1
● note
for contactor disconnection
number of NO contacts for auxiliary contacts
1
number of CO contacts for auxiliary contacts
0
● at 24 V
3 A
● at 110 V
3 A
● at 120 V
3 A
● at 125 V
3 A
● at 230 V
2 A
● at 400 V
1 A
● at 690 V
0.75 A
● at 60 V
0.3 A
● at 220 V
0.11 A
design of the miniature circuit breaker for short-circuit protection of the auxiliary switch required
6A (SCC less than equal to 0.5 kA; U less than equal to 260V)
contact rating of auxiliary contacts according to UL
B600 / R300
trip class
CLASS 10
design of the overload release
thermal
● at 480 V rated value
77 A
● at 600 V rated value
77 A
— with type of coordination 1 required
690 V: gG: 250 A; 1000 V: a.M. / g.B.: 160 A
— with type of coordination 2 required
690 V: gG: 160 A; 1000 V: a.M. / g.B.: 160 A
● for short-circuit protection of the auxiliary switch required
fuse gG: 6 A, quick: 10 A
mounting position
for mounting on contactors: with a vertical mounting plane +/-135° rotatable & +/- 22.5° tiltable, stand-alone installation: with a vertical mounting plane +/-135° rotatable and +/-45° tiltable; for more details see manual
WhatsApp