Guardamotor Automatico S3 75 - 93 A 3RV2041-4YA10 - Siemens
SKU 3RV2041-4YA10 · Unidad base: unit
Producto Siemens. Referencia del fabricante: 3RV2041-4YA10. Circuit breaker size S3 for motor protection, CLASS 10 A-release 75...93 A N-release 1300 A screw terminal Standard switching capacity Características técnicas: product designation: Circuit breaker; design of the product: For motor protection; product type designation: 3RV2; Product equipment of circuit breaker for motor protection complete unit with protection device: Yes; size of the circuit-breaker: S3; size of contactor can be combined company-specific: S3; product function disconnector functionality: Yes; product extension auxiliary switch: Yes; ● at AC in hot operating state: 39 W; ● at AC in hot operating state per pole: 13 W; type of calculation of power loss current-dependent: quadratic; insulation voltage with degree of pollution 3 at AC rated value: 1 000 V.
Ingresa o regístrate para consultar el stock registrado.
Ingresar ↗La solicitud no reserva mercadería ni confirma un pedido.
Consultar ficha técnica ↗Características del producto
- product designation
- Circuit breaker
- design of the product
- For motor protection
- product type designation
- 3RV2
- Product equipment of circuit breaker for motor protection complete unit with protection device
- Yes
- size of the circuit-breaker
- S3
- size of contactor can be combined company-specific
- S3
- product function disconnector functionality
- Yes
- product extension auxiliary switch
- Yes
- ● at AC in hot operating state
- 39 W
- ● at AC in hot operating state per pole
- 13 W
- type of calculation of power loss current-dependent
- quadratic
- insulation voltage with degree of pollution 3 at AC rated value
- 1 000 V
- surge voltage resistance rated value
- 8 kV
- ● in networks with ungrounded star point between main and auxiliary circuit
- 400 V
- ● in networks with grounded star point between main and auxiliary circuit
- 400 V
- ● on the front according to IEC 60529
- IP20
- ● on the front
- IP20
- ● of the terminal
- IP00
- shock resistance according to IEC 60068-2-27
- 25 g / 11 ms Sinus
- ● of the main contacts typical
- 25 000
- ● of auxiliary contacts typical
- 25 000
- electrical endurance (operating cycles) typical
- 25 000
- reference code according to IEC 81346-2
- Q
- continuous current rated value
- 93 A
- Substance Prohibitance (day/month/year)
- 03/01/2017
- SVHC substance name
- Lead CAS-No. 7439-92-1
- Net Weight
- 2.214 kg
- installation altitude at height above sea level maximum
- 2 000 m
- ● during operation
- -20 ... +60 °C
- ● during storage
- -50 ... +80 °C
- ● during transport
- -50 ... +80 °C
- temperature compensation
- -20 ... +60 °C
- relative humidity during operation
- 10 ... 95 %
- number of poles for main current circuit
- 3
- adjustable current response value current of the current-dependent overload release
- 75 ... 93 A
- type of voltage for main current circuit
- AC
- ● rated value
- 690 V
- ● at AC-3 rated value maximum
- 690 V
- ● at AC-3e rated value maximum
- 690 V
- operating frequency rated value
- 50 ... 60 Hz
- operational current rated value
- 93 A
- ● at AC-3 at 400 V rated value
- 93 A
- ● at AC-3e at 400 V rated value
- 93 A
- — at 230 V rated value
- 22 kW
- — at 400 V rated value
- 45 kW
- — at 500 V rated value
- 55 kW
- — at 690 V rated value
- 90 kW
- ● at AC-3 maximum
- 15 1/h
- ● at AC-3e maximum
- 15 1/h
- type of voltage for auxiliary and control circuit
- AC/DC
- number of NC contacts for auxiliary contacts
- 0
- number of NO contacts for auxiliary contacts
- 0
- number of CO contacts for auxiliary contacts
- 0
- ● ground fault detection
- No
- ● phase failure detection
- Yes
- trip class
- CLASS 10
- design of the overload release
- thermal
- protection function thermal overload protection (ANSI 49)
- Yes
- ● at AC at 240 V rated value
- 100 kA
- ● at AC at 400 V rated value
- 65 kA