Materiales eléctricos · Piura, PerúAtención a empresas y profesionales
Mi lista 0
SIEMENS Arrancador Suave Sirius S3 80 A, 30 HP/220 V, 65 HP/440 V, 200-480 V, Ac/Dc 110-230 V 3RW3046-1BB14 - Siemens 3RW3046-1BB14
SIEMENS

Arrancador Suave Sirius S3 80 A, 30 HP/220 V, 65 HP/440 V, 200-480 V, Ac/Dc 110-230 V 3RW3046-1BB14 - Siemens

SKU 3RW3046-1BB14 · Unidad base: unit

Producto Siemens. Referencia del fabricante: 3RW3046-1BB14. SIRIUS soft starter S3 80 A, 45 kW/400 V, 40 °C 200-480 V AC, 110-230 V AC/DC Screw terminals Características técnicas: product designation: Soft starter; ● integrated bypass contact system: Yes; ● thyristors: Yes; ● intrinsic device protection: No; ● motor overload protection: No; ● evaluation of thermistor motor protection: No; ● external reset: No; ● adjustable current limitation: No; ● inside-delta circuit: No; product component motor brake output: No; insulation voltage rated value: 600 V; degree of pollution: 3, acc. to IEC 60947-4-2.

Consulta existencias con tu cuenta.

Ingresa o regístrate para consultar el stock registrado.

Ingresar ↗

La solicitud no reserva mercadería ni confirma un pedido.

Consultar ficha técnica ↗

Características del producto

product designation
Soft starter
● integrated bypass contact system
Yes
● thyristors
Yes
● intrinsic device protection
No
● motor overload protection
No
● evaluation of thermistor motor protection
No
● external reset
No
● adjustable current limitation
No
● inside-delta circuit
No
product component motor brake output
No
insulation voltage rated value
600 V
degree of pollution
3, acc. to IEC 60947-4-2
blocking voltage of the thyristor maximum
1 600 V
reference code according to EN 61346-2
Q
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750
G
● at 40 °C rated value
80 A
● at 50 °C rated value
73 A
● at 60 °C rated value
66 A
— at standard circuit at 40 °C rated value
22 kW
yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value
20 hp
operating frequency rated value
50 ... 60 Hz
relative negative tolerance of the operating frequency
-10 %
relative positive tolerance of the operating frequency
10 %
operating voltage at standard circuit rated value
200 ... 480 V
relative negative tolerance of the operating voltage at standard circuit
-15 %
relative positive tolerance of the operating voltage at standard circuit
10 %
minimum load [%]
10 %
continuous operating current [% of Ie] at 40 °C
115 %
power loss [W] at operational current at 40 °C during operation typical
12 W
type of voltage of the control supply voltage
AC/DC
control supply voltage frequency 1 rated value
50 Hz
control supply voltage frequency 2 rated value
60 Hz
relative negative tolerance of the control supply voltage frequency
-10 %
relative positive tolerance of the control supply voltage frequency
10 %
control supply voltage 1 at AC at 50 Hz
110 ... 230 V
control supply voltage 1 at AC at 60 Hz
110 ... 230 V
relative negative tolerance of the control supply voltage at AC at 50 Hz
-15 %
relative positive tolerance of the control supply voltage at AC at 50 Hz
10 %
relative negative tolerance of the control supply voltage at AC at 60 Hz
-15 %
relative positive tolerance of the control supply voltage at AC at 60 Hz
10 %
control supply voltage 1 at DC
110 ... 230 V
relative negative tolerance of the control supply voltage at DC
-15 %
relative positive tolerance of the control supply voltage at DC
10 %
display version for fault signal
red
size of engine control device
S3
width
70 mm
height
170 mm
depth
190 mm
fastening method
screw and snap-on mounting
mounting position
With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° tiltable to the front and back
● upwards
60 mm
● at the side
30 mm
● downwards
40 mm
wire length maximum
300 m
number of poles for main current circuit
3
● for main current circuit
screw-type terminals
● for auxiliary and control circuit
screw-type terminals
number of NC contacts for auxiliary contacts
0
number of NO contacts for auxiliary contacts
1
number of CO contacts for auxiliary contacts
0
WhatsApp