SIEMENS Arrancador Suave Sirius S6 134 A, 50 HP/220 V, 100 HP/440 V, 200-480 V, Ac/Dc 110-230 V 3RW4055-6BB44 - Siemens 3RW4055-6BB44
SIEMENS

Arrancador Suave Sirius S6 134 A, 50 HP/220 V, 100 HP/440 V, 200-480 V, Ac/Dc 110-230 V 3RW4055-6BB44 - Siemens

SKU 3RW4055-6BB44 · Unidad base: unit

Producto Siemens. Referencia del fabricante: 3RW4055-6BB44. SIRIUS soft starter S6 134 A, 75 kW/400 V, 40 °C 200-460 V AC, 230 V AC Screw terminals !!! Phased-out product !!! Successor is SIRIUS 3RW5, Preferred successor type is >>3RW5055-6AB14<< Características técnicas: product designation: Soft starter; ● integrated bypass contact system: Yes; ● thyristors: Yes; ● intrinsic device protection: Yes; ● motor overload protection: Yes; ● evaluation of thermistor motor protection: No; ● external reset: Yes; ● adjustable current limitation: Yes; ● inside-delta circuit: No; product component motor brake output: No; insulation voltage rated value: 600 V; degree of pollution: 3, acc. to IEC 60947-4-2.

Consulta existencias con tu cuenta.

Ingresa o regístrate para consultar el stock registrado.

Ingresar ↗

La solicitud no reserva mercadería ni confirma un pedido.

Consultar ficha técnica ↗

Características del producto

product designation
Soft starter
● integrated bypass contact system
Yes
● thyristors
Yes
● intrinsic device protection
Yes
● motor overload protection
Yes
● evaluation of thermistor motor protection
No
● external reset
Yes
● adjustable current limitation
Yes
● inside-delta circuit
No
product component motor brake output
No
insulation voltage rated value
600 V
degree of pollution
3, acc. to IEC 60947-4-2
reference code according to EN 61346-2
Q
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750
G
● at 40 °C rated value
134 A
● at 50 °C rated value
117 A
● at 60 °C rated value
100 A
— at standard circuit at 40 °C rated value
37 kW
yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value
30 hp
operating frequency rated value
50 ... 60 Hz
relative negative tolerance of the operating frequency
-10 %
relative positive tolerance of the operating frequency
10 %
operating voltage at standard circuit rated value
200 ... 460 V
relative negative tolerance of the operating voltage at standard circuit
-15 %
relative positive tolerance of the operating voltage at standard circuit
10 %
minimum load [%]
20 %
adjustable motor current for motor overload protection minimum rated value
59 A
continuous operating current [% of Ie] at 40 °C
115 %
power loss [W] at operational current at 40 °C during operation typical
60 W
type of voltage of the control supply voltage
AC
control supply voltage frequency 1 rated value
50 Hz
control supply voltage frequency 2 rated value
60 Hz
relative negative tolerance of the control supply voltage frequency
-10 %
relative positive tolerance of the control supply voltage frequency
10 %
● at 50 Hz rated value
230 V
● at 60 Hz rated value
230 V
relative negative tolerance of the control supply voltage at AC at 50 Hz
-15 %
relative positive tolerance of the control supply voltage at AC at 50 Hz
10 %
relative negative tolerance of the control supply voltage at AC at 60 Hz
-15 %
relative positive tolerance of the control supply voltage at AC at 60 Hz
10 %
display version for fault signal
red
size of engine control device
S6
width
120 mm
height
198 mm
depth
250 mm
fastening method
screw fixing
mounting position
With additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t
● upwards
100 mm
● at the side
5 mm
● downwards
75 mm
wire length maximum
300 m
number of poles for main current circuit
3
● for main current circuit
busbar connection
● for auxiliary and control circuit
screw-type terminals
number of NC contacts for auxiliary contacts
0
number of NO contacts for auxiliary contacts
2
number of CO contacts for auxiliary contacts
1
● finely stranded with core end processing
16 ... 70 mm²
● finely stranded without core end processing
16 ... 70 mm²
● stranded
16 ... 70 mm²