Materiales eléctricos · Piura, PerúAtención a empresas y profesionales
Mi lista 0
SIEMENS Relé Falla Perdida Fase/Secuencia /Desbalance De Fase, 3 X 160 - 690 Vac, 1NA+ 1NC 3UG4512-1AR20 - Siemens 3UG4512-1AR20
SIEMENS

Relé Falla Perdida Fase/Secuencia /Desbalance De Fase, 3 X 160 - 690 Vac, 1NA+ 1NC 3UG4512-1AR20 - Siemens

SKU 3UG4512-1AR20 · Unidad base: unit

Producto Siemens. Referencia del fabricante: 3UG4512-1AR20. !!! product phase-out !!! the preferred successor is 3UG5512-1AR20 phase failure and sequence monitoring 3 x 160...690 V analog monitoring relay phase failure and sequence monitoring 3 x 160...690 V AC 50...60 Hz 1 changeover contact screw terminal Características técnicas: product designation: Line monitoring relay; design of the product: 2 functions; product type designation: 3UG4; product function: Phase monitoring relay; display version LED: Yes; ● with degree of pollution 3 rated value: 690 V; degree of pollution: 3; ● for monitoring: AC; surge voltage resistance rated value: 6 kV; shock resistance according to IEC 60068-2-27: sinusoidal half-wave 15 g / 11 ms; vibration resistance according to IEC 60068-2-6: 1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2 g; mechanical service life (operating cycles) typical: 10 000 000.

Consulta existencias con tu cuenta.

Ingresa o regístrate para consultar el stock registrado.

Ingresar ↗

La solicitud no reserva mercadería ni confirma un pedido.

Consultar ficha técnica ↗

Características del producto

product designation
Line monitoring relay
design of the product
2 functions
product type designation
3UG4
product function
Phase monitoring relay
display version LED
Yes
● with degree of pollution 3 rated value
690 V
degree of pollution
3
● for monitoring
AC
surge voltage resistance rated value
6 kV
shock resistance according to IEC 60068-2-27
sinusoidal half-wave 15 g / 11 ms
vibration resistance according to IEC 60068-2-6
1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2 g
mechanical service life (operating cycles) typical
10 000 000
electrical endurance (operating cycles) at AC-15 at 230 V typical
100 000
thermal current of the switching element with contacts maximum
5 A
reference code according to IEC 81346-2
K
relative repeat accuracy
1 %
Substance Prohibitance (day/month/year)
05/01/2012
SVHC substance name
Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1
Net Weight
105.08 g
● undervoltage detection
No
● overvoltage detection
No
● phase sequence recognition
Yes
● phase failure detection
Yes
● asymmetry detection
No
● overcurrent detection 1 phase
No
● overvoltage detection 3 phase
No
● undercurrent detection 1 phase
No
● undervoltage detection 3 phases
No
● voltage window recognition 3 phase
No
● adjustable open/closed-circuit current principle
No
● auto-RESET
Yes
type of voltage of the control supply voltage
AC
● initial value
1
● full-scale value
1
design of the interface bluetooth
No
response time maximum
450 ms
number of NC contacts delayed switching
0
number of NO contacts delayed switching
0
● for auxiliary contacts
1
● delayed switching
1
operating frequency with 3RT2 contactor maximum
5 000 1/h
number of poles for main current circuit
3
● at 250 V at 50/60 Hz
3 A
● at 400 V at 50/60 Hz
3 A
● at 24 V
1 A
● at 125 V
0 A
● at 250 V
0 A
operational current at 17 V minimum
5 mA
continuous current of the DIAZED fuse link of the output relay
4 A
● due to burst according to IEC 61000-4-4
2 kV
● due to conductor-earth surge according to IEC 61000-4-5
2 kV
● due to conductor-conductor surge according to IEC 61000-4-5
1 kV
field-based interference according to IEC 61000-4-3
10 V/m
electrostatic discharge according to IEC 61000-4-2
6 kV contact discharge / 8 kV air discharge
● between input and output
Yes
● between the outputs
Yes
● between the voltage supply and other circuits
Yes
product function suitable for safety function
No
protection class IP on the front according to IEC 60529
IP20
product component removable terminal for auxiliary and control circuit
Yes