
Interruptor Termomagnetico 4P 140-200 A ICU=55KA @ 220V 3VM1 3VM1220-4GE42-0AA0 - Siemens
SKU 3VM1220-4GE42-0A · Unidad base: unit
Producto Siemens. Referencia del fabricante: 3VM1220-4GE42-0AA0. circuit breaker 3VM1 IEC frame 250 breaking capacity class S Icu=36kA @ 415V 4-pole, line protection TM220, ATFM, In=200A overload protection Ir=140A...200A short-circuit protection Ii=10 x In N conductor protection 100% nut keeper kit (for products not manufactured in China, only CE and EEQCO Scheme-X certifications are available) Características técnicas: product designation: Molded case circuit breaker; design of the product: Line protection; design of the overcurrent release: TM220; protection function of the overcurrent release: LI; number of poles: 4; insulation voltage / rated value: 800 V; operating voltage / at AC / at 50/60 Hz / rated value: 500 V; operating voltage / at DC / rated value: 500 V; operating voltage / at AC / rated value: 690 V; power loss [W] / maximum: 42 W; power loss [W] / for rated value of the current / at AC / in hot operating state / per pole: 14 W; mechanical service life (operating cycles) / typical: 15 000.
Ingresa o regístrate para consultar el stock registrado.
Ingresar ↗La solicitud no reserva mercadería ni confirma un pedido.
Consultar ficha técnica ↗Características del producto
- NOME
- ITM 4P 200R
- product designation
- Molded case circuit breaker
- design of the product
- Line protection
- design of the overcurrent release
- TM220
- protection function of the overcurrent release
- LI
- number of poles
- 4
- insulation voltage / rated value
- 800 V
- operating voltage / at AC / at 50/60 Hz / rated value
- 500 V
- operating voltage / at DC / rated value
- 500 V
- operating voltage / at AC / rated value
- 690 V
- power loss [W] / maximum
- 42 W
- power loss [W] / for rated value of the current / at AC / in hot operating state / per pole
- 14 W
- mechanical service life (operating cycles) / typical
- 15 000
- electrical endurance (operating cycles) / at AC-1 / at 380/415 V
- 6 000
- product feature / for neutral conductors / upgradable/retrofittable / short-circuit and overload proof
- No
- ground-fault monitoring version
- Without
- ● communication function
- No
- ● other measurement function
- No
- Net Weight
- 2.106 kg
- ● at 40 °C
- 200 A
- ● at 45 °C
- 200 A
- ● at 50 °C
- 200 A
- ● at 55 °C
- 194 A
- ● at 60 °C
- 188 A
- ● at 65 °C
- 182 A
- ● at 70 °C
- 176 A
- switching capacity class of the circuit breaker
- S
- ● at 240 V
- 55 kA
- ● at 415 V
- 36 kA
- ● at 440 V
- 25 kA
- ● at 500 V
- 10 kA
- design of short-circuit protection
- For switching capacity values in DC power systems, see the 3VA Molded Case Circuit Breaker Manual; link available under Service & Support in the last chapter
- product feature / for L-tripping / can be switched on/off
- No
- ● minimum
- 140 A
- ● maximum
- 200 A
- design of the N-conductor protection
- 100%
- product function / grounding protection
- No
- ● undervoltage release
- No
- ● voltage trigger
- No
- ● trip indicator
- No
- height [in]
- 6.22 in
- height
- 158 mm
- width [in]
- 5.51 in
- width
- 140 mm
- depth [in]
- 2.76 in
- depth
- 70 mm
- arrangement of electrical connectors / for main current circuit
- Front connection
- type of electrical connection / for main current circuit
- nut keeper kit on both ends
- type of connectable conductor cross-sections / for flat-bar terminal connection / minimum
- 13 x 1 mm
- type of connectable conductor cross-sections / for flat-bar terminal connection / maximum
- 25 x 8 mm
- design of the surface / of the connections / on the top of the switch (N, 1, 3, 5)
- Silver
- design of the surface / of the connections / on the bottom of the switch (N, 2, 4, 6)
- Silver
- number of CO contacts / for auxiliary contacts
- 0
- product extension / optional / motor drive
- No
- protection class IP / on the front
- IP40
- ● during operation / minimum
- -25 °C
- ● during operation / maximum
- 70 °C
- ● during storage / minimum
- -40 °C
- ● during storage / maximum
- 80 °C
- CCC
- Yes
- VDE
- Yes
