Materiales eléctricos · Piura, PerúAtención a empresas y profesionales
Mi lista 0
SIEMENS Interruptor Diferencial 4X40 A, 30 Ma, Tipo AC, Modelo Sinova - Siemens (5TJ7344-0) 5TJ7344-0
SIEMENS

Interruptor Diferencial 4X40 A, 30 Ma, Tipo AC, Modelo Sinova - Siemens (5TJ7344-0)

SKU 5TJ7344-0 · Unidad base: unit

Producto Siemens. Referencia del fabricante: 5TJ7344-0. SINOPLUS, Residual Current operated circuit breaker 4-pole, Type AC, In: 40A 30mA, Un AC:415V Características técnicas: number of poles: 4; size of installation devices according to DIN 43880: 1; mechanical service life (operating cycles) typical: 5 000; short-circuit current of series fuse maximum permissible: 40 A; short-circuit current rating: 6 kA; switching function short-term delayed: No; overvoltage category: 3; degree of pollution: 2; insulation voltage (Ui) rated value: 660 V; tripping fault current rated value: 30 mA; — at 40 °C rated value: 40 A; — at 45 °C rated value: 40 A.

Consulta existencias con tu cuenta.

Ingresa o regístrate para consultar el stock registrado.

Ingresar ↗

La solicitud no reserva mercadería ni confirma un pedido.

Consultar ficha técnica ↗

Características del producto

number of poles
4
size of installation devices according to DIN 43880
1
mechanical service life (operating cycles) typical
5 000
short-circuit current of series fuse maximum permissible
40 A
short-circuit current rating
6 kA
switching function short-term delayed
No
overvoltage category
3
degree of pollution
2
insulation voltage (Ui) rated value
660 V
tripping fault current rated value
30 mA
— at 40 °C rated value
40 A
— at 45 °C rated value
40 A
— at 50 °C rated value
40 A
● operational current at AC rated value
40 A
residual current type
AC
let-through current permissible
3 kA
I2t value permissible
11 500 A²·s
supply voltage for testing equipment minimum
195 V
value range of the supply voltage frequency
50/60 Hz
value range of the operating frequency
50/60 Hz
value range of the supply voltage at AC
240/415 V
protection class IP
IP20, if the distribution board is installed, with connected conductors
switching capacity current according to IEC 61008-1 rated value
0.5 kA
● for rated value of the current at AC in hot operating state per pole
4.9 W
● maximum
19.6 W
product feature silicon-free
Yes
product extension installable supplementary devices
No
● minimum
1 mm²
position of power supply cord
top or bottom
height
84.5 mm
width
72 mm
depth
76 mm
installation depth
70 mm
number of modular width units
4
fastening method
DIN rail (REG)
mounting position
any
Net Weight
390 g
● minimum permissible
-25 °C
● maximum permissible
60 °C
number of test cycles for environmental testing according to IEC 60068-2-30
28
reference code according to IEC 81346-2
F
S Mark
Yes
Type Examination Certificate
Yes
last modified:
11/28/2025
Date 9/1/2026
Subject to change without notice © Copyright Siemens 2026